3P sync series

Kontakt

zum Kontaktformular

Service Hotline
+49 8134 9324 0

Per Email
info@3P‑instruments.com

3P sync Series

Gas adsorption analyzers

With the 3P sync series, 3P Instruments offers a new measuring instrument with up to four measuring stations and a separate p0 measuring cell for simultaneous measurement of the saturation vapor pressure. The stations and measuring cell are temperature controlled by a single cold dewar. Thus, the 3P sync enables the highest sample throughput with the smallest possible space requirement and minimum liquid nitrogen consumption. Depending on the sample volume, it can be configured individually as a 1-, 2-, 3- or 4-station instrument. In addition, the number of pressure transducers can be configured at the measuring station. If the instrument is to be equipped with the fastest possible measuring configuration, a separate pressure sensor can be integrated in each of the four measuring stations. If the measuring speed is not relevant (e.g., for measurements overnight), the measuring instrument can be equipped with only one pressure sensor for up to four measuring stations. Depending on the price/performance ratio, less than six pressure sensors can be integrated, resulting in seven different 3P sync model configurations.

Specifications/Features/Advantages

  • Up to 4 parallel analysis stations
  • Up to 6 pressure sensors for high precision / high speed analyses
  • Software-assisted presentation of isotherms and kinetic data (equilibrium pressure vs. Time)
  • Static-volumetric analysis setup
  • State-of-the-art internal pressure regulators
  • Single-/Multipoint-BET surface area (DIN 66131, ISO 9277)
  • Langmuir surface area
  • Adsorption and desorption isotherms
  • Total pore volume and average pore radius
  • NLDFT (density functional theory)
  • Mesopore size distribution according to BJH (DIN 66134) and DH method

Literatur und Normen

/1/ Single-/Multipoint BET surface analysis (DIN 66131, ISO 9277)
/2/ Mesopore size distribution according to BJH method (DIN 66134)
/3/ STSA-surface area of carbon black according to ASTM D6556
/4/ Micropore analysis (DIN 66135) according to t-plot or Dubinin-Radushkevic
/5/ Particle World 20; p. 24 – 25; “The brand new 3P sync series: Multi-station measurements at an optimal price/performance ratio”

Accessories

  • external degassing unit for 4 stations
  • sample preparation in vacuum
  • max. degasser temperature: 400 °C
  • Temperature range 77 – 323 K
  • Temperature stability ± 0.004 K (standard deviation)
  • Easy-to-use software for data acquisition, display, analysis and archiving

Tempering Kit

Tempering Kit for all sorption instruments, 0-50°C
  • For all sorption instruments, 0-50°C

Other Gas Adsorption Analyzers:

3P micro seriesUp to 3 stations, especially suitable for micropore analysis
3P meso seriesUp to 4 stations, especially suitable for mesopore analysis
3P surface DX4 stations, suitable for surface analysis
Contact

Service hotline (Germany)
+49 8134 9324 0

Contact us via Email
info@3P-instruments.com