Bettersizer S3 – Particle size and shape analysis 0.01 – 3500 µm

With its unique and innovative design, the Bettersizer S3 combines the measurement methods of static light scattering and dynamic image analysis for measuring particle size from the nanometer to the millimeter range.

Using the patented DLOIS technology, even nanoparticles (from 10 nm onward) can reliably be characterized. The additional lens between the laser and the measurement chamber enables the detection of the backscattered light. The use of only one laser with oblique incidence of light provides a continuous scattering spectrum with consistent wavelength and allows the detection in a continuous angle range up to 165°.

Since the maximal intensity of the scattered light of large particles can only be detected at very small angles, the classical static light scattering cannot analyze those particles sufficient enough. The image analysis system of the Bettersizer S3 enables, in contrast to other laser diffraction systems, the reliable detection of larger particles thanks to particle detection by camera and thus allows realistic measurements up to 3.5 mm.

Bettersizer S3 - request Analyzer

Specifications/Features/Advantages

  • particle measurement range: 0.01 – 3500 µm
  • integrated CCD camera (0.5x) for the (optionally) significantly more precise detection of coarse particles up to 3.5 mm, especially of oversized particles, compared to “plain” static light scattering.
  • innovative double lens technology (DLOIS) with an extremely wide detection angle range (0.02° – 165°) and detection in the backscattering direction for reliable measurement of even very small particles (> 10 nm)
  • single laser technology and thus consistent laser wavelength (532 nm) for all evaluations
  • short measurement time of less than one minute
  • determination of the refractive index
  • Standard operation procedures (SOP)
  • automated dispersion and circulation system
  • automatic centering function of the optics before each measurement
  • accurate calibration function
  • easy operation and intuitive software interface
  • export of the results in multiple formats such as PDF, .txt, .jpg with software flexibility for the creation of result reports and archiving of the measurement data.
  • 600 ml standard bath volume
  • compliant with ISO 13320 and 21 CFR-Part11

Bettersizer S3 – Scheme of Optical Bench

Literature and Norms

/1/ ISO 13320 Particle size analysis – Laser diffraction methods

Accessories

With the solvent resistance option and the additional dispersion unit BT-800N, measurements can be performed in all common solvents on the Bettersizer S3. The reduced bath volume compared to the standard dispersing unit enables economical use of solvents, the modular design of the measuring system and the self-sufficient operation of the dispersing unit BT-800N guarantees a quick and easy exchange of the dispersing modules without inconvenient cleaning or further modifications to hardware and software. Analogous to the standard dispersion, a visible sample preparation by stirring and ultrasonic is possible.

  • Sample volume < 300 ml
  • Ultrasonic: 50 Watt bath-sonication
  • variable pumping or stirring speed (0 – 2500 rpm)
  • appropriate for aqueous, polar and non-polar solvents

The external small-volume cell is ideally suitable for reproducible particle size measurement in polar and non-polar solvents. Due to the small amount of liquid, solvent consumption is low. The effective and controllable ultrasonic irradiation enables the measurement of systems that are difficult to disperse or tend to reagglomeration.

Cleaning and changing samples or solvents is very easy thanks to the quick release system. The sample feed to the Bettersizer S3 is carried out via a solvent-resistant hose and is manually controlled.

External small-volume cell - add option
  • Sample volume around 90 – 120 ml
  • Stainless steel agitator vessel with centrifugal pump and quick-release mechanism
  • Ultrasonic system: power: up to 200 Watt; frequency: 26 kHz – adjustable amplitude (20 – 100 %) – programming of maximum energy input
  • Touch display and automatic data storage and remote control
  • suitable for aqueous, polar and non-polar solvents

Other instruments

Bettersizer S3 Plus Static light scattering and Dynamic image analysis 0.01 – 3500 µm
Bettersizer 2600 Static light scattering 0.02 – 2600 µm
Nanoptic 90 Dynamic light scattering 1 nm – 9.5 µm
BeVision D1 Dynamic image analysis 2 µm – 10.000 µm
DT-100 Acoustic attenuation spectroscopy 5 nm – 1000 µm
DT-1202 Acoustic attenuation spectroscopy 5 nm – 1000 µm